329 research outputs found

    Association of serum uric acid with visceral, subcutaneous and hepatic fat quantified by magnetic resonance imaging

    Get PDF
    Elevated serum uric acid (SUA) is associated with a variety of medical conditions, such as hypertension, diabetes and obesity. Analyses investigating uric acid and obesity were primarily conducted using anthropometric measures like BMI and waist circumference. However, different adipose tissue depots might be differentially affected in uric acid metabolism. We analyzed the relation of SUA with visceral, subcutaneous and hepatic fat as quantified by Magnetic Resonance Imaging in N = 371 individuals from a cross-sectional sample of a population-based cohort. Associations of SUA and fat depots were calculated by regressions adjusted for potential confounders. We found that SUA was correlated with all fat measures (e.g. Pearson's r between SUA and hepatic fat: 0.50, 95%-CI: 0.42, 0.57). Associations with visceral and hepatic fat, but not with subcutaneous fat, remained evident after adjustment for anthropometric measures (e.g. visceral fat: \textgreekb = 0.51 l, 95%-CI: 0.30 l, 0.72 l). In conclusion, these results show how different adipose tissue compartments are affected by SUA to varying degrees, thus emphasizing the different physiological roles of these adipose tissues in uric acid metabolism

    Coronary Computed Tomography Angiography Based Assessment of Endothelial Shear Stress and Its Association with Atherosclerotic Plaque Distribution In-Vivo

    Get PDF
    Purpose The relationship between low endothelial shear stress (ESS) and coronary atherosclerosis is well established. ESS assessment so far depended on invasive procedures. The aim of this study was to demonstrate the relationship between ESS and coronary atherosclerosis by using non-invasive coronary computed tomography angiography (CTA) for computational fluid dynamics (CFD) simulations. Methods A total number of 7 consecutive patients with suspected coronary artery disease who received CTA and invasive angiography with IVUS analysis were included in this study. CTA examinations were performed using a dual-source scanner. These datasets were used to build a 3D mesh model. CFD calculations were performed using a validated CFD solver. The presence of plaque was assumed if the thickness of the intima-media complex exceeded 0.3 mm in IVUS. Plaque composition was derived by IVUS radiofrequency data analysis. Results Plaque was present in 32.1% of all analyzed cross-sections. Plaque prevalence was highest in areas of low ESS (49.6%) and high ESS (34.8%). In parts exposed to intermediate-low and intermediate-high ESS few plaques were found (20.0% and 24.0%) (p<0.001). Wall thickness was closely associated with local ESS. Intima-media thickness was 0.43 +/- 0.34mm in low and 0.38 +/- 0.32mm in high ESS segments. It was significantly lower when the arterial wall was exposed to intermediate ESS (0.25 +/- 0.18mm and 0.28 +/- 0.20mm) (p<0.001). Fibrofatty tissue was predominately found in areas exposed to low ESS (p <= 0.023). Conclusions In this study a close association of atherosclerotic plaque distribution and ESS pattern could be demonstrated in-vivo. Adding CFD analysis to coronary CTA offers the possibility to gather morphologic and physiologic data within one non-invasive examination

    Living systematic review and meta-analysis of the prostate MRI diagnostic test with Prostate Imaging Reporting and Data System (PI-RADS) assessment for the detection of prostate cancer:study protocol

    Get PDF
    INTRODUCTION: The Prostate Imaging Reporting and Data System (PI-RADS) standardises reporting of prostate MRI for the detection of clinically significant prostate cancer. We provide the protocol of a planned living systematic review and meta-analysis for (1) diagnostic accuracy (sensitivity and specificity), (2) cancer detection rates of assessment categories and (3) inter-reader agreement. METHODS AND ANALYSIS: Retrospective and prospective studies reporting on at least one of the outcomes of interest are included. Each step that requires literature evaluation and data extraction is performed by two independent reviewers. Since PI-RADS is intended as a living document itself, a 12-month update cycle of the systematic review and meta-analysis is planned. This protocol is in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses—Protocols statement. The search strategies including databases, study eligibility criteria, index and reference test definitions, outcome definitions and data analysis processes are detailed. A full list of extracted data items is provided. Summary estimates of sensitivity and specificity (for PI-RADS ≥3 and PI-RADS ≥4 considered positive) are derived with bivariate binomial models. Summary estimates of cancer detection rates are calculated with random intercept logistic regression models for single proportions. Summary estimates of inter-reader agreement are derived with random effects models. ETHICS AND DISSEMINATION: No original patient data are collected, ethical review board approval, therefore, is not necessary. Results are published in peer-reviewed, open-access scientific journals. We make the collected data accessible as supplemental material to guarantee transparency of results. PROSPERO REGISTRATION NUMBER: CRD42022343931

    Subclinical Cardiovascular Disease Markers in Relation to Serum and Dietary Magnesium in Individuals from the General Population

    Get PDF
    Several studies have implied a role of magnesium in the development of cardiovascular disease (CVD). Thus, magnesium might serve as a potential risk marker for early CVD. Therefore, we investigated the association of serum magnesium and dietary magnesium intake with markers of subclinical CVD in a population-based study. We used cross-sectional data from the sub-study of the Cooperative Health Research in the Region of Augsburg (KORA-FF4). Markers of subclinical CVD, namely, left and right ventricular structure and function and carotid plaque and carotid wall thickness, were derived by magnetic resonance imaging (MRI). Multivariable-adjusted regression models were applied to assess the relationship between serum and dietary magnesium and MRI-derived subclinical CVD markers. Among 396 included participants (mean age: 56.3 ± 9.2 years; 57.8% male), 181 (45.7%) had low serum magnesium levels (<2.07 mg/dL). Among 311 subjects with complete dietary data (mean age: 56.3 ± 9.1 years; 56.3% male), 154 (49.5%) had low dietary magnesium intake (≤155.2 mg/1000 kcal/day). Serum and dietary magnesium were not correlated (p-value = 0.5). Serum magnesium was significantly associated with presence of carotid plaque (OR 1.62, p-value 0.033). Dietary magnesium was associated with higher left ventricular end-systolic and end-diastolic volume (0.04 mL/m2, 0.06 mL/m2; p-value 0.011, 0.013, respectively), and also with a decrease in left ventricular remodeling index and mean diastolic wall thickness (−0.001 g/mL/m2, −0.002 mm/m2; p-value 0.004, 0.029, respectively). In summary, there was no consistent association of serum and dietary magnesium with imaging markers of subclinical CVD

    Diagnosing and mapping pulmonary emphysema on X-ray projection images

    Get PDF
    To assess whether grating-based X-ray dark-field imaging can increase the sensitivity of X-ray projection images in the diagnosis of pulmonary emphysema and allow for a more accurate assessment of emphysema distribution. Lungs from three mice with pulmonary emphysema and three healthy mice were imaged ex vivo using a laser-driven compact synchrotron X-ray source. Median signal intensities of transmission (T), dark-field (V) and a combined parameter (normalized scatter) were compared between emphysema and control group. To determine the diagnostic value of each parameter in differentiating between healthy and emphysematous lung tissue, a receiver-operating-characteristic (ROC) curve analysis was performed both on a per-pixel and a per-individual basis. Parametric maps of emphysema distribution were generated using transmission, dark-field and normalized scatter signal and correlated with histopathology. Transmission values relative to water were higher for emphysematous lungs than for control lungs (1.11 vs. 1.06, p<0.001). There was no difference in median dark-field signal intensities between both groups (0.66 vs. 0.66). Median normalized scatter was significantly lower in the emphysematous lungs compared to controls (4.9 vs. 10.8, p<0.001), and was the best parameter for differentiation of healthy vs. emphysematous lung tissue. In a per-pixel analysis, the area under the ROC curve (AUC) for the normalized scatter value was significantly higher than for transmission (0.86 vs. 0.78, p<0.001) and dark-field value (0.86 vs. 0.52, p<0.001) alone. Normalized scatter showed very high sensitivity for a wide range of specificity values (94% sensitivity at 75% specificity). Using the normalized scatter signal to display the regional distribution of emphysema provides color-coded parametric maps, which show the best correlation with histopathology. In a murine model, the complementary information provided by X-ray transmission and dark-field images adds incremental diagnostic value in detecting pulmonary emphysema and visualizing its regional distribution as compared to conventional X-ray projections

    Association between abdominal adiposity and subclinical measures of left-ventricular remodeling in diabetics, prediabetics and normal controls without history of cardiovascular disease as measured by magnetic resonance imaging: results from the KORA-FF4 Study

    Get PDF
    Objectives: Local, abdominal fat depots may be related to alterations in cardiac function and morphology due to a metabolic linkage. Thus, we aimed to determine their association with subtle cardiac changes and the potential interaction with hyperglycemic metabolic states. Methods: Subjects from the general population and without history of cardiovascular disease were drawn from the Cooperative Health Research in the Region of Augsburg FF4 cohort and underwent 3 T cardiac and body MRI. Measures of abdominal adiposity such as hepatic proton-density fat fraction [PDFFhepatic], subcutaneous (SAT) and visceral abdominal fat (VAT) as well as established cardiac left-ventricular (LV) measures including LV remodeling index (LVCI) were derived. Associations were determined using linear regression analysis based on standard deviation normalized predictors. Results: Among a total of 374 subjects (56.2 ± 9.1 years, 58% males), 49 subjects had diabetes, 99 subjects had prediabetes and 226 represented normal controls. Only subtle cardiac alterations were observed (e.g. LVCI: 1.13 ± 0.30). While SAT was not associated, increasing VAT and increasing PDFFhepatic were independently associated with increasing LVCI (β = 0.11 and 0.06, respectively), decreasing LV end-diastolic volume (β = − 6.70 and 3.23, respectively), and decreasing LV stroke volume (β = − 3.91 and − 2.20, respectively). Hyperglycemic state did not modify the associations between VAT or PDFF and LV measures (interaction term: all p ≥ 0.29). Conclusion: In a healthy population, VAT but also PDFFhepatic were associated with subclinical measures of LV remodeling without evidence for a modifying effect of hyperglycemic state

    Free Breathing Real-Time Cardiac Cine Imaging With Improved Spatial Resolution at 3 T

    Get PDF
    Objectives: The aim of this study was to evaluate free-breathing single-shot real-time cine imaging for functional cardiac imaging at 3 +/- with increased spatial resolution. Special emphasis of this study was placed on the influence of parallel imaging techniques. Materials and Methods: Gradient echo phantom images were acquired with GRAPPA and modified SENSE reconstruction using both integrated and separate reference scans as well as TGRAPPA and TSENSE. In vivo measurements were performed for GRAPPA reconstruction with an integrated and a separate reference scan, as well as TGRAPPA using balanced steady-state free precession protocols. Three clinical protocols, rtLRInt (T-res = 51.3 milliseconds; voxel, 2.5 x 5.0 x 10 mm(3)), rtMRSep (T-res = 48.8 milliseconds; voxel, 1.9 x 3.1 x 10 mm(3)), and rtHRSep ((Tres) = 48.3 milliseconds; voxel, 1.6 x 2.6 x 10 mm(3)), were investigated on 20 volunteers using GRAPPA reconstruction with internal as well as separate reference scans. End-diastolic volume, end-systolic volume, ejection fraction, peak ejection rate, peak filling rate, and myocardial mass were evaluated for the left ventricle and compared with an electrocardiogram-triggered segmented readout cine protocol used as standard of reference. All studies were performed at 3 T. Results: Phantom and in vivo data demonstrate that the combination of GRAPPA reconstruction with a separate reference scan provides an optimal compromise of image quality as well as spatial and temporal resolution. Functional values (P values) for the standard of reference, rtLRInt, rtMRSep, and rtHRSep end-diastolic volume were 141 +/- 24 mL, 138 +/- 21 mL, 138 +/- 19 mL, and 128 +/- 33 mL, respectively (P = 0.7, 0.7, 0.4); end-systolic volume, 55 +/- 15 mL, 61 +/- 14 mL, 58 +/- 12 mL, and 55 +/- 20 mL, respectively (P = 0.23, 0.43, 0.62); ejection fraction, 61% +/- 5%, 57% +/- 5%, 58% +/- 4%, and 56% +/- 8%, respectively (P = 0.01, 0.11, 0.06); peak ejection rate, 481 +/- 73 mL/s, 425 +/- 62 mL/s, 434 +/- 67 mL/s, and 381 +/- 86 mL/s, respectively (P = 0.03, 0.04, 0.01); peak filling rate, 555 +/- 80 mL/s, 480 +/- 70 mL/s, 500 +/- 70 mL/s, and 438 +/- 108 mL/s, respectively (P = 0.007, 0.05, 0.004); and myocardial mass, 137 +/- 26 g, 141 T 25 g, 141 +/- 23 g, and 130 +/- 31 g, respectively (P = 0.62, 0.54, 0.99). Conclusions: Using a separate reference scan and high acceleration factors up to R = 6, single-shot real-time cardiac imaging offers adequate temporal and spatial resolution for accurate assessment of global left ventricular function in free breathing with short examination times

    Free Breathing Real-Time Cardiac Cine Imaging With Improved Spatial Resolution at 3 T

    Get PDF
    Objectives: The aim of this study was to evaluate free-breathing single-shot real-time cine imaging for functional cardiac imaging at 3 +/- with increased spatial resolution. Special emphasis of this study was placed on the influence of parallel imaging techniques. Materials and Methods: Gradient echo phantom images were acquired with GRAPPA and modified SENSE reconstruction using both integrated and separate reference scans as well as TGRAPPA and TSENSE. In vivo measurements were performed for GRAPPA reconstruction with an integrated and a separate reference scan, as well as TGRAPPA using balanced steady-state free precession protocols. Three clinical protocols, rtLRInt (T-res = 51.3 milliseconds; voxel, 2.5 x 5.0 x 10 mm(3)), rtMRSep (T-res = 48.8 milliseconds; voxel, 1.9 x 3.1 x 10 mm(3)), and rtHRSep ((Tres) = 48.3 milliseconds; voxel, 1.6 x 2.6 x 10 mm(3)), were investigated on 20 volunteers using GRAPPA reconstruction with internal as well as separate reference scans. End-diastolic volume, end-systolic volume, ejection fraction, peak ejection rate, peak filling rate, and myocardial mass were evaluated for the left ventricle and compared with an electrocardiogram-triggered segmented readout cine protocol used as standard of reference. All studies were performed at 3 T. Results: Phantom and in vivo data demonstrate that the combination of GRAPPA reconstruction with a separate reference scan provides an optimal compromise of image quality as well as spatial and temporal resolution. Functional values (P values) for the standard of reference, rtLRInt, rtMRSep, and rtHRSep end-diastolic volume were 141 +/- 24 mL, 138 +/- 21 mL, 138 +/- 19 mL, and 128 +/- 33 mL, respectively (P = 0.7, 0.7, 0.4); end-systolic volume, 55 +/- 15 mL, 61 +/- 14 mL, 58 +/- 12 mL, and 55 +/- 20 mL, respectively (P = 0.23, 0.43, 0.62); ejection fraction, 61% +/- 5%, 57% +/- 5%, 58% +/- 4%, and 56% +/- 8%, respectively (P = 0.01, 0.11, 0.06); peak ejection rate, 481 +/- 73 mL/s, 425 +/- 62 mL/s, 434 +/- 67 mL/s, and 381 +/- 86 mL/s, respectively (P = 0.03, 0.04, 0.01); peak filling rate, 555 +/- 80 mL/s, 480 +/- 70 mL/s, 500 +/- 70 mL/s, and 438 +/- 108 mL/s, respectively (P = 0.007, 0.05, 0.004); and myocardial mass, 137 +/- 26 g, 141 T 25 g, 141 +/- 23 g, and 130 +/- 31 g, respectively (P = 0.62, 0.54, 0.99). Conclusions: Using a separate reference scan and high acceleration factors up to R = 6, single-shot real-time cardiac imaging offers adequate temporal and spatial resolution for accurate assessment of global left ventricular function in free breathing with short examination times
    • …
    corecore